500W 24V Well-Pump Solar Wiring Diagram with Battery (2S1P)

Computed 500W 24V well pump solar diagram: 2S1P array, wire gauges, OCPD, battery arrangement, routed parts and printable files.

500W 24V Well-Pump Solar Wiring Diagram with Battery (2S1P) showing 2S1P panels, MPPT controller, 2S3P battery bank, wire gauges and OCPD ratings
Computed from the values printed in the schedules below; not a permit set.
View the scalable diagram inline500W 24V Well-Pump Solar Wiring Diagram with Battery (2S1P)Computed 2S1P schematic for a 500 W 24 V well pump system, including wire and OCPD labels.FIG. OGA-LIBRARY-114500W 24V Well-Pump Solar Wiring Diagram with Battery (2S1P)COMPUTED FROM OGA CALC-CORE · NOT A PERMIT SET12 AWG · 20 A OCPD · 2.47% drop10 AWG · 30 A OCPD · 1.51% drop1/0 AWG · 125 A OCPD · 0.18% drop2 × 250 W panels2S1P · 60 Voc / 10.2 IscCombiner1 stringDC disconnect20 A DC ratedMPPT controller27 A min · 150 V max30 A OCPDController output6 × 200 Ah LiFePO₄2S3P · 15360 Wh bank125 A OCPDInverter feed1950 W inverter3900 W surge · 90.3 A DCShunt90.3 A monitored returnGround busEquipment groundingarray → controller12 AWG · 20 A OCPD · 2.47% drop20 ft one way · Coppercontroller → battery10 AWG · 30 A OCPD · 1.51% drop7 ft one way · Copperbattery → inverter1/0 AWG · 125 A OCPD · 0.18% drop2 ft one way · CopperPOSITIVENEGATIVEEQUIPMENT GROUNDFAILING SEGMENTNEC 2023 Table 310.16 (60 C column) - conductor ampacityNEC Chapter 9, Table 8 - conductor DC resistanceNEC 240.6(A) - standard overcurrent-device ratingsNEC 210.19 / 215.2 - 125% continuous-load conductor sizingNEC 690.7 - maximum PV source-circuit voltageNEC 690.8 - PV source-circuit current sizingVerify equipment terminals, listings, ambient/bundling derates and local code before installation.

What this computed plan shows

For the 500W 24V Well-Pump Solar Wiring Diagram with Battery (2S1P), a 2S1P array gives 500 W of rated panel capacity for the well pump use case. Nameplate multiplication produces 60 Voc, 51 Vmp and 10.2 Isc at the combined array. Those values are carried forward into controller and conductor checks instead of being rounded into a one-size-fits-all diagram.

At the charge controller, the drawing records a 27 A minimum and a 75 V design Voc. Those are different questions: one protects adequate charging output, while the other keeps the 2S1P string below the equipment’s 150 V input limit. Both checks return within for this exact 500W 24V Well-Pump Solar Wiring Diagram with Battery (2S1P) state.

The array-to-controller route is 20 ft one way and carries 15.9 design amps. It resolves to 12 AWG copper, a 20 A OCPD and 2.47% calculated drop. Downstream, the 7 ft controller lead uses 10 AWG copper behind 30 A protection, holding its computed drop to 1.51%.

Storage is drawn as 2S3P: 6 LiFePO₄ units, each 200 Ah. That produces 600 Ah at 24 V and 15,360 Wh nominal. The complete-series-string rule is why the count and arrangement appear together rather than as an interchangeable battery total.

A 1,950 W continuous inverter draws about 90.3 A from this 24 V bank under the stated efficiency assumption. The 2 ft feed therefore becomes 1/0 AWG copper, protected at 125 A and calculated at 0.18% drop. Keeping this high-current run short is usually more effective than buying around a poor layout.

All three schedule rows pass the shared ampacity and voltage-drop checks for the inputs printed here. That does not account for every field condition, including conduit fill, grouped conductors, engine-room heat, corrosion exposure or manufacturer-specific terminal limits. Treat the 500W 24V Well-Pump Solar Wiring Diagram with Battery (2S1P) as a traceable calculation snapshot and have work reviewed whenever the installation falls outside its displayed assumptions.

For later comparison, keep the 500 W array, 2S3P bank and the 20/7/2 ft one-way routes together when requesting equipment quotes or an inspection review.

Wire, protection and battery schedules

Wire schedule

SegmentDesign currentOne-way runComputed conductorVoltage dropSizing basis
array → controller15.9 A20 ft12 AWG copper2.47%156% of array Isc (NEC 690.8)
controller → battery20.8 A7 ft10 AWG copper1.51%controller output at 125% continuous-load ampacity
battery → inverter90.3 A2 ft1/0 AWG copper0.18%inverter continuous DC input at 90% efficiency and 125% ampacity

Overcurrent protection

Protected segmentRequired ampacityOCPDConductor ampacityVerdict
array → controller15.9 A20 A20 Awithin
controller → battery26 A30 A30 Awithin
battery → inverter112.8 A125 A125 Awithin

Battery arrangement

ArrangementChemistryUnitsUnit capacityBank capacityNominal energyNominal voltage
2S3PLiFePO₄6200 Ah600 Ah15,360 Wh24 V

Static routed parts list

Parts are computed from this passing configuration. A route appears only when the verified catalogue record proves every displayed numeric rating; all uncertain matches stay local for verification. Routed links may earn Off Grid Authority a commission at no extra cost to you.

2 × 250 W solar panelVoc 30 V, Vmp 25.5 V, Isc 10.2 AVerify locally — no proven catalogue match
6 × 200 Ah LiFePO₄ battery2S3P bank, 15360 Wh nominalVerify locally — no proven catalogue match
1 × 1950 W inverter3900 W surge, 24 V DC inputVerify locally — no proven catalogue match
50 ft × 12 AWG Copper cableTHHN/THWN-2 copper (or UL-listed battery cable), 75°C+Verify locally — no proven catalogue match
2 × Ring/lug terminalstinned, sized for 12 AWGVerify locally — no proven catalogue match
1 × 20 A breaker / fuseDC-rated, 51 V system — must not exceed the wire's 20 A ratingVerify locally — no proven catalogue match
1 pr × Heat-shrink + ferrulesadhesive-lined, color-codedVerify locally — no proven catalogue match
20 ft × 10 AWG Copper cableTHHN/THWN-2 copper (or UL-listed battery cable), 75°C+Verify locally — no proven catalogue match
2 × Ring/lug terminalstinned, sized for 10 AWGVerify locally — no proven catalogue match
1 × 30 A breaker / fuseDC-rated, 24 V system — must not exceed the wire's 30 A ratingVerify locally — no proven catalogue match
1 pr × Heat-shrink + ferrulesadhesive-lined, color-codedVerify locally — no proven catalogue match
10 ft × 1/0 AWG Copper cableTHHN/THWN-2 copper (or UL-listed battery cable), 75°C+Verify locally — no proven catalogue match
2 × Ring/lug terminalstinned, sized for 1/0 AWGVerify locally — no proven catalogue match
1 × 125 A breaker / fuseDC-rated, 24 V system — must not exceed the wire's 125 A ratingVerify locally — no proven catalogue match
1 pr × Heat-shrink + ferrulesadhesive-lined, color-codedVerify locally — no proven catalogue match

Pre-install review steps

  1. Confirm the array and controller window: Verify that the 2S1P string plan produces 60 V open circuit and that the equipment is rated above the 75 V cold-design value.
  2. Lay out the protected DC runs: Measure the one-way paths before ordering cable, then compare them with the computed 20 ft, 7 ft and 2 ft runs shown here.
  3. Build complete battery strings: Arrange all 6 battery units as 2S3P; do not leave a partial series string in a 24 V bank.
  4. Commission against equipment instructions: Check polarity, terminal torque, DC interrupt ratings, conductor temperature ratings, ambient correction and local inspection requirements before energizing the 1,950 W inverter.

Customize or compare

Customize this diagram →

Open the parent build guide for the surrounding design context, safety notes and installation discussion.